MAK-6630 is an Audio Analyzer which incorporates the measurement functions of distortion, relative Value, AC/DC level and frequency in a single instrument, and also is equipped with a low distortion audio signal source (DDS method).

FEATURES |
■ |
Owing to the adoption of the DDS method, the frequency changing speed is very fast, from 10Hz to 110kHz, and the audio signal is very high purity (-100dB at 80kHz LPF). |
■ |
In spite of one measuring system, 2-channel measurement can be capable due to the L/R signal selector circuit, and also UNBAL/BAL measurements are possible for BTL amplifiers. |
■ |
High-pass filter --- 100Hz, 200Hz, 400Hz
Low-pass filter --- 30kHz, 80kHz
Pre-Low-pass filter --- 15kHz, 20kHz
Weighting network (PSOPHO) --- IEC-AUDIO, CCIR/ARM, DIN-AUDIO standards, In addition to the above filters, a user-provided filter can be inserted by connecting it to rear-panel Input/Output connectors (EXT. FILTER). |
■ |
The reciprocal type high speed counter is equipped and the range is from 10Hz to 110kHz with ±5×10-5 |
■ |
The measuring range is from 0.03160mV to 100.0V in 7ranges and an accuracy is within ±0.4dB at 1kHz. The frequency range is from 10Hz to 110kHz. |
■ |
The mesuring range is 30mV to 100V fs and an accuracy is ±0.5% of full scale. |
■ |
This unit is capable of measuring distortion factors of the fundamental signal over the frequency from 10Hz to 110khz, and a high sensitivity 1.0mVrms range is provided for the dynamic range measurement of digital audio equipments. |
■ |
For AC level measurements, it is possible to display input levels as the relative value referred to a reference value. |
■ |
All operation functions provided on the front panel can be programmed up to 100 steps, and also the limit (GO/No-Go) judgment and memory auto-sequence functions are equipped. |
■ |
This unit is provided with GP-IB, RS-232C and EXT.I/O external control interfaces as its standard equipment so that it can be converted into an automatic measuring system. |
|
----------------------------------------------------------------------------------------------------------------------------------------- |
SPECIFICATIONS |
Oscillator |
Frequencu range |
10Hz to 110kHz (4 ranges) |
Setting resolution |
0.1Hz (10Hz to 200Hz) |
1Hz (201Hz to 2kHz) |
10Hz (2.01kHz to 20kHz) |
100Hz (20.01kHz to 110kHz) |
Setting accuracy |
±2% of setting |
Output channel |
2-output channel |
Output range |
20dBV (OPEN) |
14dBV (600Ω load end) |
+20 to -79.9dBV (OPEN) |
Resolution |
0.1 dB |
Accuracy |
±0.4 dB (at 1 kHz) |
Output impedance |
600Ω |
Frequency response |
+20dBV to -70dBV (OPEN)
|
±0.4dB 20Hz to 20kHz (at 1 kHz) |
±0.8dB 10Hz to 110kHz (at 1 kHz) |
Distortion |
3.16Vrms (typ.) |
Less than -100dB(10Hz to 15kHz, 80kHz BW) |
Less than -90dB(15.1kHz to 20kHz, 80kHz BW) |
Less than -80dB(10Hz to 110kHz, 500kHz BW) |
|
|
Measurement |
Frequency measurement |
Frequency range |
10Hz to 110kHz (AUTO/MANU) |
Display/Resolution |
5 digits display for ≥ 100Hz
0.01Hz for < 100Hz |
Accuracy |
±5×10-5 ±1 digit |
Input range |
25mV (rms) to 100.0V (rms) |
|
|
AC Level measurement |
Measurement channel |
2-CH (Switchable) |
Input method |
Unbalance and Balanced (selectable) |
Separation for 2 channels |
Better than 80dBb (at 1kHz) |
Input impedance |
100kΩ or more |
Frequency range |
10Hz to 110kHz |
Measurement range |
0.1mV to100V in 7 range(AUTO/MANU) |
Unit (m) V |
Unit dBV |
Unit dBm |
100.0V |
40.0dBV |
42.2dBm |
31.6V |
30.0dBV |
32.2dBm |
3.16V |
10.0dBV |
12.2dBm |
316.0mV |
-10.0dBV |
-7.8dBm |
31.6mV |
-30.0dBV |
-27.8dBm |
3.160mV |
-50.0dBV |
-47.8dBm |
0.316mV |
-70.0dBV |
-67.8dBm |
|
|
Effective measuring range |
0.0316mV (-90dB) to 100V (40dB) |
Accuracy |
Within±0.4dB for 40dB to -70dB (at 1kHz) |
Frequency response |
40dBV to -70dBV |
Within±0.8dB for 10Hz to 110kHz at 1kHz ref.
Within±0.4dB for 20Hz to 80kHz at 1kHz ref. |
Measuring resolution |
0.1% of full scale value for each range |
|
|
DC Level Measurement |
Measurement channel |
1-CH |
Input impedance |
1MΩ or more |
Range |
300mV FS to 100.0V FS(4 ranges) |
Accuracy |
±0.5% of full scale value |
Measurement resolution |
0.1% of full scale value |
|
|
Distortion Measurement |
Fundamental frequency range |
10Hz to 110kHz(AUTO/MANU) |
Measurement resolution |
0.1% of full scale value for each range |
Input range |
7 ranges |
Unit (m) V |
Unit dBV |
Unit dBm |
100.0V |
40.0dBV |
42.2dBm |
31.6V |
30.0dBV |
32.2dBm |
10.0V |
20.0dBV |
22.2dBm |
3.16V |
10dBV |
12.2dBm |
1.0V |
0dBV |
2.2dBm |
0.316V |
-10.0dBV |
-7.8dBm |
0.1V |
-20.0dBV |
-17.8dBm |
|
|
Measurement range display |
7 ranges |
Unit(%) |
Unit(dBV) |
31.6% |
-10dB |
10.0% |
-20dB |
3.16% |
-30dB |
1.0% |
-40dB |
0.316% |
-50dB |
0.1% |
-60dB |
0.0316 |
-70dB |
|
|
Residual distortion |
3.16Vrms(typ.) |
-100 dB Less than (10 Hz to 15 kHz 80 kHz BW)
-90 dB Less than (15.1 kHz to 20 kHz 80 kHz BW)
-80 dB Less than (10 Hz to 110 kHz 500 kHz BW) |
Input level range |
0.1V(rms) to 100V(rms) |
Accuracy |
Within±1dB for 20Hz to 20kHz |
Accuracy at 2nd harmonic |
Within±3dB for 10Hz to 110kHz |
Amplifie for digital audio |
60dB |
|
|
Other |
Filters |
• HPF |
100 Hz, 200 Hz, 400 Hz |
• LPF |
30 kHz, 80 kHz |
• PRE LPF |
15 kHz, 20 kHz |
• PSOPHO |
CCIR / ARM, DIN-AUDIO, IEC-A |
• EXTERNAL |
EXT |
Memory function |
100points(Memory address 00 to 99) |
Interface function |
GP-IB, RS-232C, EXT.I/O |
|
|
General Data |
Operating temperature range |
0ºC to +50ºC |
Guarantee temperature range |
+15ºC to +35ºC |
Power requirement |
AC 90V to AC 132V/AC 198V to 250V |
Dimmensions |
Approx. 426 (W) × 100 (H) × 460 (D) mm |
Weight |
Approx. 12kg |
|
* |
Specifications are subject to change without notice. |
|
|
|
|
|